Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathA3COM-HUAWEI-MAC-INFORMATION-MIB
executable file
·402 lines (348 loc) · 14 KB
/
A3COM-HUAWEI-MAC-INFORMATION-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
-- ============================================================================
-- Copyright (c) 2004-2009 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: The purpose of this MIB file is to provide the definition of
-- the MAC Information general configuration.
-- Reference:
-- Version: V1.1
-- History:
-- V1.0 2007-12-28
-- Initial version, created by gejianzhuang
-- V1.1 2009-08-13
-- Add 'h3cMACInformationTrapObjectsExt' by gejianzhuang
-- ============================================================================
A3COM-HUAWEI-MAC-INFORMATION-MIB DEFINITIONS ::= BEGIN
IMPORTS
h3cCommon
FROM A3COM-HUAWEI-OID-MIB
Unsigned32, Counter32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
ifIndex
FROM IF-MIB;
-- Node definitions
h3cMACInformation MODULE-IDENTITY
LAST-UPDATED "200712281912Z" -- DEC 28, 2007 at 19:12 GMT
ORGANIZATION
"Hangzhou H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"This MIB file is to provide the definition of the MAC Information
general configuration. MAC Information feature is used to
make that the changed MAC information in the monitored device is
knowable in remote monitoring device."
REVISION "200712281912Z"
DESCRIPTION
"The initial version of this MIB file."
::= { h3cCommon 87 }
H3cMACInfoWorkMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The working mode of the MAC Information feature."
SYNTAX INTEGER
{
trap(1),
syslog(2)
}
h3cMACInformationObjects OBJECT IDENTIFIER ::= { h3cMACInformation 1 }
h3cMACInformationMibGlobal OBJECT IDENTIFIER ::= { h3cMACInformationObjects 1 }
h3cMACInformationMIBTableTroop OBJECT IDENTIFIER ::= { h3cMACInformationObjects 2 }
h3cMACInformationMibTrap OBJECT IDENTIFIER ::= { h3cMACInformationObjects 3 }
h3cMACInformationMibTrapExt OBJECT IDENTIFIER ::= { h3cMACInformationObjects 4 }
h3cMACInformationEnabled OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is a global setting. The feature will not work until the
value is set to enabled(1). If the value is set to disabled(2),
the feature will stop working even there are interfaces that have
been enabled the feature."
DEFVAL { disabled }
::= { h3cMACInformationMibGlobal 1 }
h3cMACInformationcSendInterval OBJECT-TYPE
SYNTAX Unsigned32(1..20000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum interval that the device generate syslogs or traps.
The unit is second."
DEFVAL { 1 }
::= { h3cMACInformationMibGlobal 2 }
h3cMACInformationLearntMACNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MAC addresses that learnt by the device since the
h3cMACInformationEnabled is set to enabled(1) and h3cMACLearntEnable
is set to enabled(1) at least on one interface. If the h3cMACInformationEnabled
is set to disabled(2), the object will always return 0."
::= { h3cMACInformationMibGlobal 3 }
h3cMACInformationRemovedMACNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MAC addresses that removed by the device since the
h3cMACInformationEnabled is set to enabled(1) and h3cMACRemovedEnable
is set to enabled(1) at least on one interface. If the h3cMACInformationEnabled
is set to disabled(2), the object will always return 0."
::= { h3cMACInformationMibGlobal 4 }
h3cMACInformationTrapSendNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of traps that have been generated. This object is valid
only when the h3cMACInfomationWorkMode is set to trap(1). If the
h3cMACInfomationWorkMode is set to syslog(2), the object will always return 0."
::= { h3cMACInformationMibGlobal 5 }
h3cMACInformationSyslogSendNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of syslogs that have been generated. This object is valid only
when the h3cMACInfomationWorkMode is set to syslog(2). If the
h3cMACInfomationWorkMode is set to trap(1), the object will always return 0."
::= { h3cMACInformationMibGlobal 6 }
h3cMACInformationCacheLen OBJECT-TYPE
SYNTAX Unsigned32(0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum queue lenth used to cache the changed MAC addresses information
in the monitored device. If the value is set to 0, syslog or trap will generate
as soon as there is a MAC address learnt or removed."
DEFVAL { 50 }
::= { h3cMACInformationMibGlobal 7 }
h3cMACInfomationWorkMode OBJECT-TYPE
SYNTAX H3cMACInfoWorkMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The working mode of MAC Information feature. If the object is
set to trap(1), the device will use trap mode to notify the MAC
address information and all properties of trap interrelated is
valid. If the object is set to syslog(2), the device will use
syslog mode to notify the MAC address information and all
properties of trap interrelated is invalid."
::= { h3cMACInformationMibGlobal 8}
--h3cMACInfomationIfTable
h3cMACInfomationIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cMACInfomationIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to enable or disable the MAC Information feature
on interfaces."
::= { h3cMACInformationMIBTableTroop 1 }
h3cMACInfomationIfEntry OBJECT-TYPE
SYNTAX H3cMACInfomationIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of h3cMACInfomationIfTable."
INDEX
{
ifIndex
}
::= { h3cMACInfomationIfTable 1 }
H3cMACInfomationIfEntry ::= SEQUENCE
{
h3cMACLearntEnable INTEGER,
h3cMACRemovedEnable INTEGER
}
h3cMACLearntEnable OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the object is set to enabled(1) on interface, the device
will cache the MAC address information that learnt on the interface."
DEFVAL { disabled }
::= { h3cMACInfomationIfEntry 1 }
h3cMACRemovedEnable OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the object is set to enable(1) on interface, the device
will cache the MAC address information that removed on the interface."
DEFVAL { disabled }
::= { h3cMACInfomationIfEntry 2 }
-- h3cMACNotificationTrap
h3cMACInformationTraps OBJECT IDENTIFIER ::= { h3cMACInformationMibTrap 0 }
h3cMACInformationChangedTrap NOTIFICATION-TYPE
OBJECTS
{
h3cMACInfoTrapIndex,
h3cMACInfoTrapCount,
h3cMACInfoTrapMsg
}
STATUS current
DESCRIPTION
"When the cached number of MAC address information is reached the
value specified by h3cMACInformationCacheLen, trap is generated
and is sent to the remote monitoring device. The trap is also
generated when the amount of time elapsed since the previous
notification is greater than the interval value specified by
h3cMACInformationcSendInterval and there is at least one cached
MAC address information learnt or removed. The object is valid
only when h3cMACInfomationWorkMode is set to trap(1). When the
h3cMACInfomationWorkMode is set to syslog(2), No trap will be
generated even h3cMACInformationEnabled is set to enabled(1) and
the feature is enabled on interface."
::= { h3cMACInformationTraps 1 }
h3cMACInformationTrapObjects OBJECT IDENTIFIER ::= { h3cMACInformationMibTrap 2 }
h3cMACInfoTrapIndex OBJECT-TYPE
SYNTAX Unsigned32(1..4294967295)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The sequence number of trap information. When it reaches the
maximum value, it should be set to 1."
::= { h3cMACInformationTrapObjects 1 }
h3cMACInfoTrapCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The cell number of the current trap information. The trap
message may consists of more than one MAC address information.
Each of the one MAC address information in one trap is called cell."
::= { h3cMACInformationTrapObjects 2 }
h3cMACInfoTrapMsg OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..254))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the MAC information that learnt or removed
in the monitored device. It can consists of more than
one MAC information in the object.
This object is in the format of '<cell1><cell2>...'. Each
cell consists of 12 octets in the format of
'<operationType><VLAN><MAC><MACtype><ifIndex>'.
<operationType> is the reason type of MAC address changed and have
size of 1 octet. It only supports the following values.
1 - MAC learnt.
2 - MAC removed.
<VLAN> is the vlan number that correspond to the MAC address in
MAC address table and has size of 2 octet.
<MAC> is the MAC address and has size of 6 octets.
<MACtype> is the MAC address type and has size of 1 octet. It only
supports the following values.
0 - Unknown
1 - Learnt
2 - Config dynamic
3 - Config static
4 - Blackhole
5 - Security
6 - 802.1x
7 - MAC authentication
8 - Voice VLAN
9 - WAPI
<ifIndex> is the index of the interface where the MAC
address is learnt or removed and has size of 2 octets."
::= { h3cMACInformationTrapObjects 3 }
-- h3cMACNotificationTrapExt
h3cMACInformationTrapsExt OBJECT IDENTIFIER ::= { h3cMACInformationMibTrapExt 0 }
h3cMACInformationChangedTrapExt NOTIFICATION-TYPE
OBJECTS
{
h3cMACInfoTrapVerExt,
h3cMACInfoTrapIndexExt,
h3cMACInfoTrapCountExt,
h3cMACInfoTrapMsgExt
}
STATUS current
DESCRIPTION
"When the cached number of MAC address information is reached the
value specified by h3cMACInformationCacheLen, trap is generated
and is sent to the remote monitoring device. The trap is also
generated when the amount of time elapsed since the previous
notification is greater than the interval value specified by
h3cMACInformationcSendInterval and there is at least one cached
MAC address information learnt or removed. The object is valid
only when h3cMACInfomationWorkMode is set to trap(1). When the
h3cMACInfomationWorkMode is set to syslog(2), No trap will be
generated even h3cMACInformationEnabled is set to enabled(1) and
the feature is enabled on interface."
::= { h3cMACInformationTrapsExt 1 }
h3cMACInformationTrapObjectsExt OBJECT IDENTIFIER ::= { h3cMACInformationMibTrapExt 2 }
h3cMACInfoTrapVerExt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The version of trap information."
::= { h3cMACInformationTrapObjectsExt 1 }
h3cMACInfoTrapIndexExt OBJECT-TYPE
SYNTAX Unsigned32(1..4294967295)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The sequence number of trap information. When it reaches the
maximum value, it should be set to 1."
::= { h3cMACInformationTrapObjectsExt 2 }
h3cMACInfoTrapCountExt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The cell number of the current trap information. The trap
message may consists of more than one MAC address information.
Each of the one MAC address information in one trap is called cell."
::= { h3cMACInformationTrapObjectsExt 3 }
h3cMACInfoTrapMsgExt OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..254))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the MAC information that learnt or removed
in the monitored device. It can consists of more than
one MAC information in the object.
This object is in the format of '<cell1><cell2>...'. Each
cell consists of 14 octets in the format of
'<operationType><VLAN><MAC><MACtype><ifIndex>'.
<operationType> is the reason type of MAC address changed and have
size of 1 octet. It only supports the following values.
1 - MAC learnt.
2 - MAC removed.
<VLAN> is the vlan number that correspond to the MAC address in
MAC address table and has size of 2 octet.
<MAC> is the MAC address and has size of 6 octets.
<MACtype> is the MAC address type and has size of 1 octet. It only
supports the following values.
0 - Unknown
1 - Learnt
2 - Config dynamic
3 - Config static
4 - Blackhole
5 - Security
6 - 802.1x
7 - MAC authentication
8 - Voice VLAN
9 - WAPI
<ifIndex> is the index of the interface where the MAC
address is learnt or removed and has size of 4 octets."
::= { h3cMACInformationTrapObjectsExt 4 }
END