Skip to content

Latest commit

 

History

History
52 lines (33 loc) · 1.63 KB

CHANGELOG.md

File metadata and controls

52 lines (33 loc) · 1.63 KB

CHANGELOG

The format is based on Keep a Changelog, and this project adheres to Semantic Versioning.

1.0.0 - 2025-1-30

Added

  • All commands according to data sheet

Changed

  • You need to call scd4x_init(SCD41_I2C_ADDR_62); before sending any command
  • all methods that have been named xxxTicks are now named xxxRaw
  • getDataReadyFlag has been renamed to getDataReadyStatus
  • scd4x_get_automatic_self_calibration/scd4x_set_automatic_self_calibration has been renamed to scd4x_get_automatic_self_calibration_enabled/scd4x_set_automatic_self_calibration_enabled
  • signature of scd4x_get_serial_number has changed

0.2.2 - 2021-04-30

Changed

  • Increase timing for single shot from 1350ms to 5000ms
  • Increase timing for self test from 5500ms to 10000ms

0.2.1 - 2021-03-01

Fixed

  • Changelog links fixed.

0.2.0 - 2021-03-01

Added

  • Convenience interfaces taking care of unit conversion to and from ticks.

Fixed

  • wake-up interface handles missing ACK from sensor on wake up.

0.1.0 - 2021-02-04

Initial release