The format is based on Keep a Changelog, and this project adheres to Semantic Versioning.
1.0.0 - 2025-1-30
- All commands according to data sheet
- You need to call scd4x_init(SCD41_I2C_ADDR_62); before sending any command
- all methods that have been named xxxTicks are now named xxxRaw
- getDataReadyFlag has been renamed to getDataReadyStatus
- scd4x_get_automatic_self_calibration/scd4x_set_automatic_self_calibration has been renamed to scd4x_get_automatic_self_calibration_enabled/scd4x_set_automatic_self_calibration_enabled
- signature of scd4x_get_serial_number has changed
0.2.2 - 2021-04-30
- Increase timing for single shot from 1350ms to 5000ms
- Increase timing for self test from 5500ms to 10000ms
0.2.1 - 2021-03-01
- Changelog links fixed.
0.2.0 - 2021-03-01
- Convenience interfaces taking care of unit conversion to and from ticks.
- wake-up interface handles missing ACK from sensor on wake up.
0.1.0 - 2021-02-04
Initial release