Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathdocker-run.sh
executable file
·121 lines (102 loc) · 2.33 KB
/
docker-run.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
#!/bin/bash
main() {
/opt/collectd/sbin/collectdmon -c /opt/collectd/sbin/collectd
./collectd-vsphere
}
write_collectd_config() {
local conf=/opt/collectd/etc/collectd.conf
cat <<EOF >$conf
# Set by Librato
Interval 60
LoadPlugin syslog
<Plugin syslog>
LogLevel info
</Plugin>
LoadPlugin cpu
LoadPlugin interface
LoadPlugin load
LoadPlugin memory
LoadPlugin ping
EOF
for host in $COLLECTD_VSPHERE_PING_AMQP_HOSTS; do
cat <<EOF >>$conf
<Plugin ping>
Host "$host"
Interval 1.0
Timeout 0.9
MaxMissed 10
</Plugin>
EOF
done
for host in $COLLECTD_VSPHERE_PING_DNS_HOSTS; do
cat <<EOF >>$conf
<Plugin ping>
Host "$host"
Interval 1.0
Timeout 0.9
MaxMissed -1
</Plugin>
EOF
done
cat <<EOF >>$conf
Include "/opt/collectd/etc/collectd.conf.d/librato.conf"
# REQUIRED for Cisco SNMP info
LoadPlugin snmp
Include "/opt/collectd/etc/collectd.conf.d/snmp.conf"
LoadPlugin network
<Plugin "network">
<Listen "127.0.0.1" "1785">
SecurityLevel "Encrypt"
AuthFile "/opt/collectd/etc/collectd-network-auth"
</Listen>
</Plugin>
EOF
conf=/opt/collectd/etc/collectd.conf.d/librato.conf
host=$(hostname)
cat <<EOF >$conf
LoadPlugin write_http
<Plugin write_http>
<Node "${host}">
URL "https://collectd.librato.com/v1/measurements"
Format "JSON"
BufferSize 8192
User "${COLLECTD_VSPHERE_LIBRATO_EMAIL}"
Password "${COLLECTD_VSPHERE_LIBRATO_TOKEN}"
</Node>
</Plugin>
EOF
conf=/opt/collectd/etc/collectd.conf.d/snmp.conf
cat <<EOF >$conf
<Plugin snmp>
<Data "ifmib_if_octets64">
Type "if_octets"
Table true
Instance "IF-MIB::ifName"
Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
</Data>
<Data "ifmib_if_packets64">
Type "if_packets"
Table true
Instance "IF-MIB::ifName"
Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
</Data>
<Data "cpu_percentage">
Type "percent"
Table true
Instance "HOST-RESOURCES-MIB::hrDeviceDescr"
Values "HOST-RESOURCES-MIB::hrProcessorLoad"
</Data>
<Host "TravisCI-Prod-FW">
Address "${COLLECTD_VSPHERE_FW_IP}"
Version 2
Community "${COLLECTD_VSPHERE_FW_SNMP_COMMUNITY}"
Collect "ifmib_if_octets64" "ifmib_if_packets64"
Interval 60
</Host>
</Plugin>
EOF
conf=/opt/collectd/etc/collectd-network-auth
echo "$COLLECTD_VSPHERE_COLLECTD_USERNAME: $COLLECTD_VSPHERE_COLLECTD_PASSWORD" >$conf
}
write_collectd_config
main